At a site with a historic gasoline release, Mundell supervised the installation of carbon filtration systems in homes found to have drinking water impacts, conducted drinking water samples from over twenty surrounding homes and at a nearby school to verify that no other drinking water sources were impacted, and installed two air mitigation systems in order to address vapor intrusion concerns within the on-site station building……Read More »
Portfolio
Mundell & Associates is a small consulting company with large-company credentials and significant experience with some of the most challenging and diverse environmental concerns.
Our project portfolio (which includes case histories, publications, and presentations) covers the world and includes time sensitive investigations as well as long term remediation and monitoring. Clients benefit from a cross disciplinary approach to problem solving and depend on our abilities to communicate complex scientific and engineering principles.
All Case Histories
Delineation of Impacts and Vapor Intrusion Mitigation Associated with a Former Dry Cleaner
Mundell was retained to provide consulting services at a former dry cleaner facility in Muncie, Indiana, where, despite several phases of subsurface investigation by other consultants, chlorinated volatile organic compound (cVOC) soil and groundwater impacts were not delineated on-site. Among the activities Mundell completed included collecting groundwater grab samples at on- and off-site Geoprobe™ soil boring locations to provide a semi-quantitative assessment of the relative distribution and concentration of downgradient cVOC impacts and completing a geophysical assessment to identify possible subsurface conduits. Mundell’s aggressive and thorough investigative actions over a one-year period provided a more concise and detailed understanding of the environmental issues associated with the site……Read More »
Proposed Trail Assessment – Madison Indiana
Mundell was retained to perform a Phase I Environmental Site Assessment (ESA) of a proposed trail area in Madison, Indiana. Mundell recommended a further evaluation of the identified potential environmental concerns including direct push geoprobing to test subsurface soil and groundwater in the vicinity of the potential concerns……Read More »
PCB Evaluation and 40 CFR 761.61 Self-directed Cleanup
Mundell researched parcel ownership information and evaluated aerial photos and flood records to piece together a better understanding of a client site where polychlorinated biphenyl (PCB) was detected in the subsurface. While the findings were being considered in ongoing legal proceedings, Mundell worked with the EPA to develop a self-directed cleanup plan to guarantee the most potential resale value for the client……Read More »
Irrigation Well Exploration Using Geophysical Methods
Mundell located several highly productive water channels on a 325 acre site in a time/cost effective manner using geologic information and 2D resistivity profiles……Read More »